About
Features & Benefits
- Water Resistant
- Thermostat and boiler control compatible
- Customizable pre-time and post-time
- Three status lights for system monitoring and diagnostics
- Welded relay protection with redundant motor relays
- Limited reset and limited recycle
- Sleek, modern design
- Technician Pump Prime mode
- 5-Year Warranty
- 7505a replaces Honeywell R8184G
- 7505b replaces Honeywell R7184B
- Two communication ports for adding alarm contacts, programming display, and/or future
Electrical Ratings
Inputs
-
- Voltage: 102 to 132 Vac
- Current: 150 mA plus burner motor, igniter, and valve loads
- Frequency: 60 Hz
Outputs
-
- Motor: 120 Vac, 10 full load amps (FLA*), 60 locked rotor amps
(LRA)- Note – Reduce motor FLA rating by igniter current
- Igniter: 120 Vac, 3 A @ 0.7 PF min
- Solenoid Valve: 120 Vac, 1 A @ 0.7 PF min
- Thermostat Anticipator Current: 0.1 A
- Thermostat Voltage: 24 Vac
- Motor: 120 Vac, 10 full load amps (FLA*), 60 locked rotor amps
Application Ratings
-
- Oil Burner Input: < 20gph
- Control Programming: UL372 Group 2
Environmental Ratings
-
- Storage & Operating Ambient Temperature: -40°F to +150°F (-40°C to +65°C)
- Moisture: 5 to 95% RH, non-condensing and non-crystallizing
Approvals
-
- Underwriters Laboratory Recognition per UL372 and UL1998,
and CSA C22.2 No. 199
- Underwriters Laboratory Recognition per UL372 and UL1998,
Available Models for GeniSys® 7505 120V Oil Burner Control
Control Part Number | Lockout Time | Valve-On Delay Time1 |
Motor-Off Delay Time1 |
7505A0000 | 15 sec | – | – |
7505B1500 | 15 sec | 15 sec | – |
7505P1515 | 15 sec | 15 sec | 15 sec |
7505P1530 | 15 sec | 15 sec | 30 sec |
7505P152M | 15 sec | 15 sec | 2 min |
1 Valve-on delay and motor-off delay timings on all models are programmable with Beckett GeniSys® Contractor Tool.
GeniSys® 7505 120V Oil Burner Control Cross-Reference
Manufacturer | Model | Lockout | Valve-On Delay Time1 |
Motor-Off Delay Time1 |
Beckett GeniSys® 7505 120V Oil Burner Control Recommended Replacement |
Carlin | ||||
40200-02 | 15 sec | 0 | 0 | 7505A0000 |
42230-02 | 30 sec | 0 | 0 | 7505A0000 |
48245 (Intermittent Ignition) |
45 sec | 0 | 0 | 7505A0000 |
50200-02 | 15 sec | 0 | 0 | 7505A-0000 (+ 52040 Alarm Module) |
60200-02 | 15 sec | 10 sec | 10 sec | 7505P-1515 (+ 52040 Alarm Module) |
Honeywell | ||||
R7184A1000 R7184A1026 R7184A1075 |
15 sec | 0 | 0 | 7505A-0000 |
R7184A1018 R7184A1034 |
7505A-0000 | |||
R7184A1042 | 45 sec | 0 | 0 | 7505A-0000 |
R7184B1016 R7184B1024 R7184B1032 |
15 sec | 0 | 0 | 7505B-1500 |
R7184P1080 | 15 sec | 15 sec | 15 sec | 7505P-1515 |
R7184P1056 R7184P1064 |
15 sec | 15 sec | selectable | 7505P-1515 |
R7184P1049 R7184P1072 R7184U1004 |
15 sec | 0 – 15 sec | selectable | 7505P-152M (+ 52040 Alarm Module) |
R7184U1012 | 30 sec | 0 – 15 sec | selectable | 7505P-152M (+ 52040 Alarm Module) |
R7184U1020 | 45 sec | 0 – 15 sec | selectable | 7505P-152M (+ 52040 Alarm Module) |
R8184G (Intermittent Ignition) |
15, 30, or 45 sec | 0 | 0 | 7505A-0000 |
R8184P (Intermittent Ignition) |
15 or 45 sec | 15 sec | 4 min | 7505P-152M |
R8184M (Intermittent Ignition) |
45 sec | 0 | 0 | 7505A-0000 (+ 51950 A/C Ready Kit) |
White Rogers | ||||
668-364 668-601 |
15 sec | 0 | 0 | 7505A-0000 |
668-264 668-501 |
30 sec | 0 | 0 | 7505A-0000 |
668-401 668-430 |
45 sec | 0 | 0 | 7505A-0000 |
668-451 | 45 sec | 0 | 0 | 7505A-0000 (+ 51950 A/C Ready Kit) |
1 Valve-on delay and motor-off delay timings on all models are programmable with Beckett GeniSys® Contractor Tool.
GeniSys® Contractor Tool
Add a GeniSys® Contractor Tool to fully utilize the features of the GeniSys advanced burner control. The GeniSys® Contractor Tool allows a technician to monitor and program the primary control variables. The display shows current burner status, control timings, and burner cycle history. The display’s programming mode allows a technician to customize both the pretime and post-time settings and a lockout service message.
Downloads & Links
Warranty
Please note, all warranty claims must be initiated through an authorized Beckett supplier/distributor. Distribution policies will not allow Beckett to directly handle warranty claims with installers and/or consumers.