Details
Overall Dimensions
Combustion Chamber Dimensions
Firing Rate (gph) | Minimum Dimensions | |||
Refractory Lined |
Wet-based Boilers | |||
A | L | A | L | |
1.65 to 2.00 | 5.5″ | 12.0″ | 5.5″ | 12.0″ |
2.00 to 3.75 | 6.0″ | 15.0″ | 6.0″ | 20.0″ |
Specifications
Operation: On/Off
Rate: 1.65 to 3.75 GPH
Fuels:
- No. 1 or No. 2 heating oil (ASTM D396)
- ASTM D396 for B6 – B20 biodiesel blends
Motor:
- 1/7 HP 3450 RPM PSC
- 120/60 Hz Standard
- 1.7 amps @ 120 VAC
Ignition Trans.: 120V/12,000V
Housing: Cast aluminum
Fuel Unit: 100 to 200 psig
Oil Nozzle: 45˚ to 70˚ Solid
Cross-References
Burner Cross-Reference:
- Carlin: 102CRD
- Riello: F10
Commercial Burner Motors:
- 21805U – PSC (1/7HP; 3450RPM; 120Vac)
Commercial Burner Pumps:
- Suntec: 2591U – A2YA-7916 (single phase; 7GPH@100psi)
- Suntec: 21188U – B2YA-8916 (2- phase; 7GPH@100psi)
- New York City Oil Pumps / DAR Kits: 51871U – B2TA-8248/DAR Mounted (single phase; 8GPH@100psi)
Transformer & Electronic Igniters with base plate:
- 51771U – Igniter with Beckett ‘A’ Base
- 51826U – Igniter with Carlin 100 Base
Typical Sequence of Operation
One-pipe Oil Flow with “B” Pump
Two-pipe Oil Flow with “B” Pump
Legend
a Return port; b Nozzle port; c Oil valve; d Nozzle & adapter; g Inlet port; k Return line to oil tank; p Air bleed valve
Downloads & Links
Warnings (prop65)
Warranty
Please note, all warranty claims must be initiated through an authorized Beckett supplier/distributor. Distribution policies will not allow Beckett to directly handle warranty claims with installers and/or consumers.